Provenly accurate adjustment in FLO plenum boxes

According to recent report from a sovereign institution, FLO plenum boxes meet the requirements of adjustment accuracy class 1. This means that the adjustment position of the devices remains within ± 5% of that designed, which is remarkable when considering the balanced operation of the ventilation system.

Adjustment accuracy classes are given for terminal devices and plenum boxes, depending on the margin of error in their adjustment. Class 1 allows a maximum variance of 5% between the designed and actual airflows, for class 2 up to one tenth difference is allowed. These differences must remain at the same level even after the control section has been removed, for example during maintenance. The range of the devices’ adjustment is also considered when testing the devices. Precise adjustment and a wide adjustment range are therefore prerequisites for achieving measurement accuracy of class 1.

FLO combines precise adjustment and reliable locking

The high dimensional accuracy of FLO plenum boxes is ensured by a unique control section that measures the pressure difference across the control section instead of pressure difference between the room and the device. In this way a very high accuracy is achieved. Additionally, the adjustment position remains in place with a reliable SlideFix locking mechanism.

FLO is suitable for both OLO and HALO diffusers for suspended ceiling systems. With FLO’s proven precision in adjustment and the directed throw pattern of the terminal devices, draft-free and controlled indoor climate can be designed at offices, business premises and school sites.

Accurate equipment for controlled ventilation system

If inaccurate devices are used in the ventilation system, a device-specific error will affect the operation of all devices throughout the entire channel system. Especially at low air volumes and duct velocities, supply air left in the duct may be significantly less than planned for the last devices.

Using the precise and pre-adjusted FLO also significantly speeds up simplifying the adjustment process and ensuring accurate air volumes and sound levels. Preset values ​​are obtained directly from the designs, from MagiCAD, and Revit, and ventilation designers can rest assured that the devices operate within the desired airflow and sound range.

 

Nyheter

Three ways UV lamp choice affect maintenance costs in professional kitchens

The use of UV light in professional kitchen air purification is common, but in terms of efficient grease purification and life cycle costs, selecting the right technology makes all the difference. We list three factors of UV applications that help in controlling maintenance costs and make the work of the kitchen staff easier.

Läs mer

Säker och bra arbetsmiljö i professionella kök kräver optimal belysning

Belysningens roll i ett professionellt kök är betydelsefull för säkerheten och som en komfortfaktor för de anställda. Kravet för belysningen styrs av den internationella inomhusbelysningsstandarden EN 12464, som reglerar tröskelvärdena för belysning i termer av bländning, färgåtergivning och ljusets tillräcklighet. Standarden har också legat till grund för produktutvecklingen av OptiLumo – Climecons ljus armatur för kökskåpor i professionella kök.

Läs mer

Svarta kåpor kompletterar inredningen i restauranger

Svarta kåpor har varit ett önskemål bland krögarna sedan länge och nu har deras önskemål infriats. Alla kåpor och ventilationstak i Climecons sortiment finns nu att få i svart design. Climecons kåpor i utförande med svart design presenterades som nyhet på FinnBuild-mässan i oktober.

Läs mer