ECO-F is the ECO series’ supply air vent with a heating element for flush mounting on walls. The stylish vent combines excellent air and sound performance with smooth surface, extremely low profile and finished design.

Duct sizes

Ø 125 mm

Installation method

Flush mounting

Installation

For wall installation

Heating

Yes

Description

ECO-F has a low profile and rectangular perforation. It has been developed based on the highly popular FINO supply air diffuser. In addition to excellent air and sound performance, it provides a stylish interior design element.

The good-looking valve is easy to install and keep clean due to its innovative structural features. ECO-F works silently. It can be controlled conveniently and accurately with innovative magnetic tapes. The device is suitable for use anywhere from bedrooms to larger spaces and corridors.

ECO – forced air heating in passive houses

The energy requirement of heating in passive houses is only 20–30 kWh/GSM and 10–20 W/m2 in rooms. The power demand for heating is small, so the accurate ECO forced air heating system that reacts quickly to changes is very suitable for these houses in terms of energy efficiency.

With the programmable ECO series, the temperature can be adjusted separately for each room and the system learns as it is used, ensuring even better energy efficiency and thermal comfort.

ECO-F Features:

  • Smooth surface, very low profile and stylish design, easy to keep clean
  • Good mixing ratio, reliable measurement and accurate control
  • Heating integrated with the ventilation system simplifies the amount of building services
  • Outside the heating season, ECO-F functions as a top-quality supply air diffuser

Quick guide

Dimensions

Dimensioning

The graph is not intended for adjusting.

Throw pattern and length

ECO-F Lb = 0,7 x L0,2

Heating on:  ECO-F Lb = 1,0 x L0,2

The supply air temperature does not affect throw-length. With warmer suplly air, the width of the throw pattern increases.

Throw length

Based on the values of a device being fully open and at least 100 mm from the ceiling.

The supply air temperature does not affect the throw-length.

Sound attenuation

Sound level increases in case the distance is less than 3xØd:

  • after curve  +4 dB (A)
  • after t-branch +8 dB (A)

Advanced scheduling of heating improves energy efficiency

Room temperatures and heating can be scheduled even for each day individually. Weekly timer enables energy savings during times spent away from home and in times when heating is not needed. The room temperature can be programmed to descend during night times in rooms where heating is not needed.

ECO room control unit learns from and adapts to its surroundings. It will be able to begin heating no sooner or later than necessary and ensures that the desired temperature is reached at the right moment.

Air heater unit technical data

Voltage: 230 VAC / 50Hz
Conectors: 2 x 2,5 mm2 (PE) supply voltage. 4 x 0,8 mm2 data transfer/ RS485 (Modbus)
Power max: Nominal voltage 400 W (6-20 dm3 /s)
Duct size: Ø125